Chromatograph
1. Chromatograph
2. Flow Controller
3. Peristaltic Pump
4. Fraction Collector
5. UV Monitor
6. Recorder
1. Chromatograph
| BioChromatograph
II |
AC-5300 |
 |
|
Measurement data being inputted can be either printed simultaneously or
once saved as digital data on a memory of the recorder. The recorder
simultaneously records measurement data inputted from up to 2
instruments. The saved measurement data can be printed later with an
option of printing parameters, and further be stored in a floppy disk,
so that the measurement data can be processed with a spreadsheet
software such as Excel in your PC. |
Go to page top
2. Flow controller
| Gradicon III |
AC-5900 |
|
|
Multi-function flow controller in which, in addition to pump flow
(increased/decreased) control, mixed concentration ratio of two kinds of
liquid is changed continuously and varieties of liquids are switched are
also possible.
 | Gradient formation by controlling 2 pumps, or 1
pump and a 3-way switching valve.
|
 | Linear gradient: 4 patterns, Exponential
gradient: 5 patterns, Stepwise gradient: 7 steps.
|
 | Stepwise switching of 8 liquids by controlling 8
solenoid valves. |
|
| Gradi-Mixer |
AC-5905 |
|
|
Electromagnetic valve unit for concentration gradient formation of 2
liquids. In combination with "Gradicon III", various kinds of
concentration gradient formation are possible using Perista Pump and
time control of port-switching of the valve. |
Go to page top
3. Peristaltic pump
Go to page top
4. Fraction collector
Go to page top
5. UV monitor
| UV Monitor |
AC-5100 / 5200
types |
  |
|
Optical
monitors to measure UV absorbance of column effluents at the wavelength
of either 280 or 254 nm in low-pressure liquid chromatography. The
dual-beam and the dual silicone photodiode detector ensure the
measurement with low noise and long-term stability over wide
environmental temperature range, affording reliable operation in a cold
room. An economy type featuring 0.0005 AU noise level, 0.0002 AU/h
stability, 5 sensitivity ranges and a high-grade type featuring 0.0002
AU noise level, 0.0005 AU/h stability, 9 sensitivity range as well as
sophisticated operations. |
Go to page top
6. Recorder
| DegiMini Recorder
|
AC-5150 |
 |
|
Measurement data being inputted can be either printed simultaneously or
once saved as digital data on a memory of the recorder. The recorder
simultaneously records measurement data inputted from up to 2
instruments. The saved measurement data can be printed later with an
option of printing parameters, and further be stored in a floppy disk,
so that the measurement data can be processed with a spreadsheet
software such as Excel in your PC. |