1. Microplate Indexing System

This indexing system aligns the 8 pin replicator (87V-478) to appropriate
wells in a 96 well microplate. This provides a very simple method of placing
the replicator pins into the center of the wells by using a 4 set series of guide
pins on the top of the indexing system and the pair of alignment holes in the
bottom of the Replicator. This registration system also is adjustable so y ou
can remove your specimen from the very bottom of your microplate or PCR
plat well, i.e., you can harvest from very small volumes even the dregs of the
well.
This indexer will accommodate all standard heght 96 well microplates that
conform to the
Society of Biomolecular Screening Standards. Many of the 96 well pp PCR
plates are smaller (length and width) than SBS Standard and need to be
shimmed for the correct registration. We provide shims for your convenience.

bulletEliminate the possibility of getting specimens from the wrong wells.
bulletKeeps the pins in the center of the well so the size of the spots remain uniform.
This is very important especially in 384 well microplates.
bulletKeeps track of which set of wells you are spotting from and where the
next group of wells will be.
bulletAccelerates the rate of the arraying process.
bulletPrevents the pins from being damaged on the bottom and sides of the
wells.

 

Cat. No: 87V-472
Microplate Indexing System for 96 Well Microplates
Cat. No: 87V-472B
Microplate Indexing System for 96 Well PCR Microplates
Cat. No: 87V-472A
Microplate Indexing System for 384 Well Microplates

 

2. Registration Systems

2.A) FU-MEEI REGISTRATION SYSTEM


For "Xeroxing" blots onto membranes with MULTI-BLOT™ Replicators .
The Fu-Meei Registration System provides an efficient way of making identical DNA blots on multiple small membranes
(xeroxing). It has its own built in three pin spindle system (87V- 440) for registering the Replicator to the membrane that also
registers the blots to locating (reference/spindle) holes punched in the membrane.
The locating hole features allows image analysis equipment convenient reference features to locate and identify positive blots. Furthermore
our custom paper punch (87V- 441) is a convenient way to punch holes in many nylon membranes (87V- 502) simultaneously
and place a hundred or more of them on the three pin spindle for blotting. The spacing of the hole pattern also is used to orient
the user to location of the blots, right from left and top from bottom.
The Fu-Meei Registration System may also be used to make high density arrays by using MULTI-PRINTS that have a 2 by 2 array
alignment pattern (87V-382F1) for 384 Pin MULTI-BLOT™ Replicators, a 3 by 3 array alignment pattern (87V- 382F2), and 4 by
4 array alignment pattern (87V- 382F3) for 96 Pin MULTI-BLOT™ Replicators. When making high density arrays we recommend
that you use the 87V- 409 MULTI BLOT™ Replicator or 87V- 386 MULTI-BLOT™ Replicator.

87V-382 Registers Replicator to large membrane
3 x 3 array for 96 Pin Replicator
2 x 2 array for 384 Replicator
87V-382B Registers Replicator to large membrane
4 x 4 array
For 96 Pin Replicator
87V-382CS Registration Device for CLONESAVER 96
CARD
87V-382D Registers Replicator to large membrane
3 x 3 & 2 x 2 array
For 96 Pin Replicator

 

MULTI-PRINT™

87V-382F For Fu-Meei Registration System
One alignment position
For 384 Pin Replicator
87V-382F1 For Fu-Meei Registration System
2 x 2 alignment array
For 96 Pin Replicator
87V-382F2 For Fu-Meei Registration System
3 x 3 alignment array
For 96 Pin Replicator
87V-382F3 For Fu-Meei Registration System
4 x 4 alignment array
For 96 Pin Replicator
87V-440 Fu-Meei 3 Pin Registration Spindle Platform
87V-441 Fu-Meei Registration Membrane Punch

 

2.B) VICKI ULTRA HIGH DENSITY ARRAY & REGISTRATION SYSTEM


The Vicki Ultra High Density Array & Registration System provides a rapid fail safe method of making 4 ultra high density
arrays from nine separate 384 well microplates (9 X 384 = 3456 individual specimen blots) on a membrane. Each spot contains
~20 ul of specimen. The membrane can then be cut into 4 identical pieces and processed independently or saved for later assays.
If you need to screen large DNA, cDNA, EST or RNA libraries this is the system for you.

The operation procedure is the essence of simplicity:

bulletA 87V- 381V Library Copier is placed over a 384 well microplate to register the microplate to the Vicki Spring Loaded
MULTI-BLOT™ Replicator housing (87V- 386V) containing a 87V- 386VR1 Vicki Replicator. The external edges of the Replicator
housing, index to an indentation in the LIBRARY COPIER™ thus assuring that the pins are positioned over the center
of the wells. The spring handle is depressed lowering the pins into the contents of the wells and the liquid is picked up on
the pin tips as ~20 ul hanging drops when the handle is raised.
bulletThe external edges of the MULTI-BLOT™ Replicator housing indexes into a window frame opening and rests on the membrane
while the Replicator pins are in the retracted position. The spring handle is depressed causing the Replicator pins to simultaneously
blot the membrane.
bulletThis process is repeated in all four window panels using the same source plate and then the alignment pins are placed in the
next pair of alignment holes and the whole process repeated using a new 384 well plate. Multiple window frames may be used if
more than 4 identical blots are needed.

 

 

 

 

 

 

 

The blot to the right was made from nine, 384 well
microplates (3,456 spots). Note that each set of 9
spots is distinct because of the spacing pattern between
pins. Each spot contains ~20 hl of specimen.
When using the Vicki Registration system you
have the freedom to choose the density of your
blots by simply selecting which of the 9 possible
blotting positions you use.

 

87V-386V Vicki Spring loaded replicator housing
87V-386VR1 Vicki 384 Pin Replicator, delivers 20 nl
87V-381V Vicki Library Copier
87V-386VF Vicki Ultra High Density Registration Window Frame

Questions

Q: How should I practice making arrays with Replicators and the registration devices? A: Just add a dye (food color works fine) to the buffer, media or solutions that you will be arraying. Do not put the dye into just
water as the surface tension of plain water is very high and will give you variable results. A little DNA, protein or carbohydrate
makes a big difference. If your buffer doesn't or can't contain these substances you can treat the pins with our 87V-110
Surfactant , or dip the pins in ETOH and flame them.
Q: When making arrays with the MULTI-PRINT™ should I use blotting paper under the membrane? A: Yes. We sell a wicking paper (87V- 521V 22cm x 32cm) that works quite well to support the membrane for 4 MULTIPRINTS,
however Whatman, 3M or other similar paper will also work.

 

2.C) LIBRARY COPIER™

bulletCOPY CULTURES, GENOMIC DNA OR cDNA LIBRARIES IN EITHER 96 OR 384 WELL FORMATS
Cosmids - Mutants - Recombinant Clones - Hybridomas - Plasmids - YACs
The LIBRARY COPIER™ is a simple registration accessory that precisely aligns the pins in our 48, 96, 384 or 1536 pin
MULTI-BLOT™ Replicators to the center of the wells in source and recipient 48, 96, 384 or 1536 well plates.
The single hole alignment pair is used on both the source and recipient plates to copy the library. The ease and precision of the alignment ensures a safe plate to plate transfer of cultures or clones, without "touching off" the hanging drop.

 

bulletCONVERT 96 WELL FORMAT LIBRARIES INTO THE 384 WELL FORMAT OR 384 WELL LIBRARIES INTO
THE 1536 WELL FORMAT
In addition to the advantages of working with high density cultures, condensing and freezing libraries in 384 well plates saves precious freezer space.

 

bulletCONSTRUCT LIBRARY "BLOCK POOLS" FOR SCREENING
The LIBRARY COPIER™ is also used to make library "block pools" by making multiple inoculations to a single recipient plate from multiple source plates. Screening "block pools" greatly reduces the number of screening assays and facilitates looking for rare events or cultures.

 

bulletREGISTER SOURCE MICROPLATE FOR COLONY COPIER™ AND MULTI-PRINT™
Because the LIBRARY COPIER™ registers the MULTI-BLOT™ Replicators to the source plates it is used in all applications:
replicating, screening, inoculating, transferring, converting, constructing and storing.

 

 

 

 

87V-381 LIBRARY COPIER™ registers MULTI-BLOT™ Replicators to 96 and 384 well microplates
87V-381A LIBRARY COPIER™ registers Deep Well MULTI-BLOT™ Replicators to deep well microplates
87V-381B LIBRARY COPIER™ registers Deep Well MULTI-BLOT™ Replicators to conventional microplates
87V-381C LIBRARY COPIER™ registers MULTI-BLOT™ Replicators to 48 well microplates
87V-381D High Throughput LIBRARY COPIER™ registers MULTI-BLOT™ Replicators to 96 and 384 well
microplates
87V-381F Corning 1536 well LIBRARY COPIER™ registers 87V-838FP1 1536 MULTI-BLOT™ Replicators to
the low volume 2 nl well 1536 Corning microplates and - FP1, - FP3, and - FP9 series Replicators.
87V-381M Midi Deep Well LIBRARY COPIER™ registers standard MULTI-BLOT™ Replicators to Midi Deep
Well microplates
87V-381N FP Replicator series LIBRARY COPIER™ registers - FP1, - FP3 & - FP9 series Floating MULTIBLOT
™ Replicators to 96 , 384 & 1536 well microplates that conform to the SBS Standards for
microplates

 

2.D) COLONY COPIER™

 

The COLONY COPIER™ is a simple registration accessory for 48, 96 and 384 pin MULTI-BLOT™ Replicators.
The COLONY COPIER™ is placed over a Nunc Omni Tray and aligns itself to the external surfaces of the Omni Tray and precisely
registers the MULTI-BLOT™ Replicator's stainless steel pins to the interior of the Omni Tray. High density offset arrays of blots or
colonies are produced on a single Omni Tray by inoculation at each alignment hole pair using our unique system of guide pins and
alignment hole pairs.

 

INOCULATE 48 TO 1536 CULTURES ON A SINGLE AGAR PLATE:
Antibiotic sensitivity assays - Drug sensitivity assays  Growth assays - Plaque assays

•SCREEN HIGH DENSITY GRIDS OF CULTURES, GENOMIC DNA OR cDNA LIBRARIES ON PRECUT
MEMBRANES:
Cosmids - Mutants - Plasmids - Recombinant clones - YACs

•CONSTRUCT AND SCREEN HIGH DENSITY ARRAYS OF:
cDNA - RNA - Antibodies - Drugs - PCR products - DNA - Antibiotics - Antigens - Ligands - Receptors

•TRANSFER ORDERED LIBRARIES OR SUBSTANCES TO MEMBRANES
FOR ASSAY:
Avidin-biotin - Hybrid selection -Ligand binding - Hybridization - Immunoassay- Receptor binding

•ACCOMMODATES WIDE VARIETY OF DETECTION METHODS:
Chemiluminescent - Chromogenic (enzyme based) -Fluorescent Isotopic

•STORE WORKING CULTURE LIBRARIES ON AGAR Culture libraries can be inoculated onto agar Omni Trays, grown into colonies and stored in the refrigerator for 7 to 8 weeks. In this format the
colonies are used as a working reference library, and the master library is spared frequent freeze/thaw cycles that may decrease culture viability and increase the risk of contamination. You can access the colony library by simply using the replicator to "pick" the colonies and transfer them to your test media or solid substrate.
Usually there is enough colony transferred that you do not have to
wait for the cultures to grow.

•PICK CLONES FROM SCREENING
PLATES WITH 384 PIN REPLICATOR
Whole libraries can also be screened
in mass and colonies or plaques
"picked" in mass from Omni Trays
with the 384 pin MULTI-BLOT™
Replicator registered to a COLONY
COPIER™. This procedure is far
more efficient and superior to individually
picking colonies or plaques
                                                                                              with tooth picks. We re commend the
                                                                                              87v- 384 Replicator because of its larger
                                                                                              pin size.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLONY COPIER

87V-380
bullet

Registers 96 pin MULTI-BLOT™ Replicators to the Omni Tray for high density
arrays (9 x 96 = 864).

bullet

Registers 48 pin MULTI-BLOT™ Replicators to the Omni Tray for high density
arrays (9 x 48 = 432).

bullet

Registers 384 pin MULTI-BLOT™ Replicators to the Omni Tray for high density

87V-380D 4 X 4 array for 96 pin replicator
 
  info@genprice.com
GENTAUR EUROPE Tel: +32 16 58 90 45 Fax: +32 16 58 90 45 Av. de l'Armée 68 • B-1040 BRUSSELS • BELGIUM
GENTAUR FRANCE Tel: 01 43 25 01 50 Fax: 01 43 25 01 60 9, Rue Lagrange • 75005 PARIS • FRANCE
GENTAUR ITALY Tel: 02 36 00 65 93 Fax: 02 36 00 65 94 20135 MILANO • ITALY
GENTAUR GERMANY Tel: +32 16 58 90 45 Fax: +32 16 58 90 45  
JAPAN Tel: +81 78 386 2860 Fax: +81 78 306 0296

Products : Bioxys, HIV p24, TNF a, IFN gamma, Agarose, Promotions Genoprice

 

About Gencompare | Contact Us | Privacy Policy |Disclaimer