Liquid Waveguide Capillary Cell(LWCC)
| 1. Visible
Spectrophotometers |

 | Square cuvette adapter included |
 | Test tube holders for as large as 1” diameter test tubes |
 | COD vial holder |
 | Glassware & NIST traceable standards available |
| Specifications: |
|
|
| Mode |
Cat. No: 55-1100 |
Cat. No: 55-1100RS |
| Special slit width: |
20nm |
10nm |
| Optical
system: |
Single beam,
grating System
1200 lines/min |
Single beam,
grating System
1200 lines/min |
Wavelength
range: |
335-1000nm(visible) |
335-1000nm(visible) |
Wavelength
accuracy: |
±2nm |
±2nm |
| Repeatability: |
±1nm |
±1nm |
| Stray light: |
£0.5%T at 340 & 400nm |
£0.5%T at 340 & 400nm |
Photometric
range: |
0-125%T, 0-2A |
0-125%T, 0-2A, 0-1999C(0-1999F) |
Photometer
accuracy: |
±2.0%T |
±1.0%T |
| Light source: |
Tungsten-Halogen lamp |
Tungsten-Halogen lamp |
| Data output: |
Analog output |
Analog output, RS-232C |
| Dimensions: |
408Wmm x 308Dmm x 185Hmm |
408Wmm x 308Dmm x 185Hmm |
| Weight: |
6kg |
6kg |
| |
Complete with 10mm test tube cuvettes
(12/box), 10mm cuvette adapter, Dust
cover, Operator’s manual |
Complete with 10mm test tube cuvettes(12/box),
10mm cuvette adapter, Dust cover, Operator’s
manual, RS-232C Serial port, |

| Specifications: |
|
| Mode |
Cat. No: 55-1200 |
| Special slit width: |
5nm |
| Optical system: |
Single beam, grating System
1200 lines/min |
| Wavelength range: |
325-1000nm(visible) |
| Wavelength accuracy: |
±2nm |
| Repeatability: |
±1nm |
| Stray light: |
£0.5%T at 340 & 400nm |
| Photometric range: |
0-125%T, 0-2.0A, 0-1999C
(0-1999F) |
| Photometer accuracy: |
±1.0%T |
| Light source: |
Tungsten-Halogen lamp |
| Data output: |
RS-232C output |
| Dimensions: |
408Wmm x 308Dmm x 185Hmm |
| Weight: |
6kg |
Ordering
Information |
|
| Cat. No: |
Description |
| 55-1200 |
Spectrophotometer – 5nm bandpass. Complete
with 10mm single square cuvette holder, universal
test tube holder, 10mm test tube (12/box), a pair of
optical glass cuvettes, RS-232C port, Dust cover,
and operator’s manual |
| 55-1200-101 |
Universal test tube holder with
base for 8 to 25mm
diameter test tubes including COD |
| 55-1200-102 |
Single cell holder with base for 10mm square
cuvettes |
| 55-1200-103 |
4-Position cell holder for 10mm
square cuvettes |
| 55-1200-104 |
Longpass 4-position cell holder for up to 50mm
rectangular cuvettes |
| 55-1200-105 |
Water jacketed 10mm single cell
holder with base
and panel for temperature control
applications.(requires water bath) |
| 55-1200-505 |
Replacement lamp |
| 2. Visible &
UV/VIS Spectrophotometer |
 | Fully flexible, easy-to-use |
 | Provide maximum performance expected from precise optics. |

| Specifications: |
|
|
| Mode |
Cat. No: 55-2100 |
Cat. No: 55-2100UV |
| Special slit width: |
5nm |
5nm |
| Optical system: |
Single beam, grating System
1200 lines/min |
Single beam, grating System
1200 lines/min |
Wavelength
range: |
335-1000nm(visible) |
200-1000nm(UV/Vis.) |
Wavelength
Accuracy:
Repeatability:
Readability: |
±2nm
±1nm
1nm |
±2nm
±1nm
1nm |
| Stability: |
±0.002A/hr @ 500nm |
±0.002A/hr @ 500nm |
| Stray light: |
£0.3%T at 340 & 400nm |
£0.3%T at 220 & 340nm |
Photometric range
& accuracy: |
0-125%T, -0.1-2.5A,
0-1999C(0-1999F)
±0.004 A @ 0.5A |
0-125%T, -0.1-2.5A,
0-1999C(0-1999F)
±0.004 A @ 0.5A |
Standard cell
holder: |
4-position |
4-position |
| Light source: |
Tungsten-Halogen lamp |
Tungsten-Halogen/Deuterium lamp |
| Data output: |
Two-line 9-LED displays, Trans., Abs.,
Conc., and wavelength, RS-232C,
Analog output |
Two-line 9-LED displays, Trans., Abs., Conc.,
and wavelength, RS-232C, Analog output |
| Dimensions: |
470Wmm x 400Dmm x 140Hmm |
408Wmm x 308Dmm x 185Hmm |
| Weight: |
10kg |
12kg |
| |
Ordering Information for
accessory package |
| Cat. No: |
Description |
| 55-2100-101P |
Test tube package for 8 to 20mm diameter tet tubes.
Includes
universal base, one holder, and top hat for up to 150mm tall test
tubes |
| 55-2100-102P |
Rectangular Longpath cell package
for cells up to 100mm
pathlength. Includes universal base & one holder |
| 55-2100-103P |
Single 10mm cuvette package. Includes universal base
& one holder |
| 55-2100-104P |
Cylindrical cell
package for cells up to 100mm pathlength. Includes
universal base & one holder |
| 55-2100-105P |
Water jacketed single cuvette package for 10mm
cuvettes for
temperatures from 0 to 95°C. Includes universal base, one holder, &
flow-thru panel. (requires water bath) |
| 55-2100-106P |
Microcell package for use with 10mm
microcuvettes. Includes
adjustable
x-y base & holder. |
| 55-2100-107P |
Peltier temperature control package for 25, 30 &
37°C. Includes
10mm cell holder, panel, adjustable x-y base & thermal electric
temperature controller. |
| 55-2100-108P |
Ambient flowcell package. Includes
peristaltic pump, flow-thru
controller, Flow-thru panel & tubing (requires flowcell) |
| 55-2100-109P |
Peltier flowcell package for 25, 30 & 37°C. Includes
peristaltic
pump, temperature/flow-thru controller, flow-thru panel, tubing &
adjustable x-y base (requires flowcell) |
| 3. UV/VIS Scanning
Spectrophotometer |
 | Fast, easy operation from the keypad |
 | PC software analysis is simple to sue and understand … |
 | Select the accessory to match your needs …. |
 | Temperature control with choices |
| Specifications: |
|
|
| Mode |
Cat. No: 55-2202 |
Cat. No: 55-2202A |
| Special slit width: |
2nm |
2nm |
| Optical system: |
Single beam, grating System
1200 lines/min |
Single beam, grating System
1200 lines/min |
Wavelength
range: |
200-1000nm(visible) |
200-1000nm(UV/Vis.) |
Wavelength
Accuracy:
Repeatability: |
±0.5nm
±0.5nm |
±0.5nm
±0.5nm |
| Display |
2 x 20 LCD |
2 x 20 LCD |
| Stability: |
±0.002A/hr @ 500nm |
±0.002A/hr @ 500nm |
| Stray light: |
£0.2% @ 220nm & 340nm |
£0.2%T at 220 & 340nm |
Photometric range
& accuracy: |
0-200%T, 0-3.0A, 0-1999C(0-1999F)
0.004A @0.5A |
0-200%T, 0-3.0A, 0-1999C(0-1999F)
0.004A @0.5A |
Sample
compartment: |
10mm 4-cell holder, manual |
10mm 4-cell holder, automatic |
| Scanning |
Yes (PC required) |
Yes (PC required) |
| capability: |
|
|
| Output display: |
%T/Abs/Conc |
%T/Abs/Conc |
| Light source: |
Halogen & Deuterium lamp |
Halogen/Deuterium lamp |
| Data output: |
Two-line 9-LED displays, Trans.,
Abs.,
Conc., and wavelength, RS-232C,
Analog output |
Two-line 9-LED displays, Trans.,
Abs., Conc.,
and wavelength, RS-232C, Analog output |
| Dimensions: |
580Wmm x 450Dmm x 200Hmm |
408Wmm x 308Dmm x 185Hmm |
| Weight: |
20kg |
20kg |

| |
Ordering Information for
accessory package |
| Cat. No: |
Description |
| 55-2100-101P |
Test tube package for 8 to 20mm diameter tet tubes.
Includes
universal base, one holder, and top hat for up to 150mm tall test
tubes |
| 55-2100-102P |
Rectangular Longpath cell package
for cells up to 100mm
pathlength. Includes universal base & one holder |
| 55-2100-103P |
Single 10mm cuvette package. Includes universal base
& one holder |
| 55-2100-104P |
Cylindrical cell package for cells
up to 100mm pathlength. Includes
universal base & one holder |
| 55-2100-105P |
Water jacketed single cuvette package for 10mm
cuvettes for
temperatures from 0 to 95°C. Includes universal base, one holder, &
flow-thru panel. (requires water bath) |
| 55-2100-106P |
Microcell package for use with 10mm
microcuvettes. Includes
adjustable
x-y base & holder. |
| 55-2100-107P |
Peltier temperature control package for 25, 30 &
37°C. Includes
10mm cell holder, panel, adjustable x-y base & thermal electric
temperature controller. |
| 55-2100-108P |
Ambient flowcell package. Includes
peristaltic pump, flow-thru
controller, Flow-thru panel & tubing (requires flowcell) |
| 55-2100-109P |
Peltier flowcell package for 25, 30 & 37°C. Includes
peristaltic
pump, temperature/flow-thru controller, flow-thru panel, tubing &
adjustable x-y base (requires flowcell) |
| 55-2100-515 |
Tungsten-halogen lamp |
| 55-2100-525 |
Deuterium lamp |
| 4. TIDAS II
Photodiode Array Spectrophotometer |
 | High performance fiber optic-based photodiode array spectrophotometer |
 | Single and multiple cuvette holder |
 | Temperature control |
 | Magnetic stirrer |
 | Ultra low noise level: 50 mAU @ 550nm |
 | Most efficient fiber coupling |
| |
Tidas II
Specifications |
| Optical basic: |
Diode-array-spectrometer with
ceramic chasis, Single beam system, Fiber
optics beam shaper instead of entrance slit, Zeiss multiplayer filter,
Optimized
for fiber optics, External fiber optics coupling free off loss of light
switched by
controlling software |
| Light sources: |
35W deuterium – 20W/6V tungsten lamp
Light mixed with Y-coupler |
| Wavelength range: |
187 – 1023nm |
| Measuring speed: |
12 ms/spectrum |
| Number of diodes: |
1024 |
| Resolution: |
0.8nm/pixel |
Wavelength
accuracy:
Reproducibility: |
±0.1nm
±0.07nm |
| Noise at 550nm: |
±2.5 x 10-5 AU |
| Baseline Drift: |
5 x 10-4 AU/h |
| Dimensions: |
18.5 x 49 x 47cm |
| Weight: |
18.5kg |
| PC Interface: |
Serial RS-422 interface (included) |
| System: |
Windows 95/95, Windows NT, Windows
2000 |
| Controller software: Spectralys for Windows: |
Absorbance, Transmittance, Counts, Concentration,
Multi-calibration, Auto-Rate-Assay, Multi-Wavelength measurement,
Spectral
smoothing, Derivative (up to D4), Active X control |
 
| |
Ordering information |
| Cat. No: |
Description |
| 79-TIDAS-BASIC |
Tidas II Basic (Stationary cuvette holder, Spectralys
software) |
| 79-TIDAS-10CUV |
Cuvette changer for 10 cuvettes |
| 79-TIDAS-TEMP |
Temperature control for Stationary cuvette holder
(5 - 100°C, ±0.1°C) |
| 79-TIDAS-TEMP10 |
Temperature control for cuvette
changer
(5 - 60°C, ±0.1°C) |
| 79-STIR |
Magnetic stirrer |
| 79-TIDAS-D2 |
Deuterium replacement lamp |
| 79-TIDAS-H |
Halogen replacement lamp, 2.2W |
| 79-TIDAS-H2 |
Halogen replacement lamp, 7.5W |
| 79-TIDAS-NIST |
UV certification to NIST |
| 79-TIDAS2-SPT |
System Tidas II, SPT-2, UCK |
| 79-TIDAS2-MV |
System Tidas II, Mvette, FO-200AS/SMA (two), LV140,
79-58200 |
| 79-TIDAS2-LWCC |
System Tidas II, LWCC2100,
FO-400-SMA1M (two), 79-501609, 79-58006,
& Peri-Star |
| |
Specify line voltage |
| 5. TIDAS I
Monolithic Spectrometer Module |
 | The first high end spectrometer module designed for fiber optic based
sampling
techniques |
 | Outperforms conventional bench-based spectrophotometers and CCD-based
spectrometer
modules, when it comes to high precision fiber optic sampling. |
 | Microtiter sampling systems for UV/VIS applications can be assembled,
using our
SpectroPipetter(SPT-2), DipTipÔ or MicroVetteÔ, as well as
fluorescence-based
systems |
| |
Tidas I Specifications |
| Optical basic: |
Monolithic spectrometer
module. Singel beam system. Fiber optic cross section
for increased light throughout instead of entrance slit. Zeiss
multiplayer filter,
Hamamatsu photodiode array detector, 16 bit. |
| Wavelength range: |
195 – 730nm |
Spectral bandwidth
(FWHM) |
5nm |
| Number of diodes: |
256 |
| Resolution: |
2.2nm/pixel |
Wavelength
accuracy:
Reproducibility: |
±0.2nm
±0.02nm |
| Noise at 550nm: |
±0.5 x 10-5 AU (using FO-6000) |
| Baseline Drift: |
5 x 10-4 AU/h |
| Dimensions: |
6.3 x 10.6 x 128” |
| Weight: |
8kg |
| PC Interface: |
Serial RS-232 interface |
| System: |
350MHz P III. 64Mbyte, Windows 95/2000, Windows NT |
| Digital inputs(outputs): |
5/5 |
Spectralys Software
(for Windows): |
Absorption, Transmission, Counts, Concentration,
Multi-calibration, Multi-
Wavelength measurement, Spectral smoothing, Derivative (up to D4),
Microprogramming |


| |
Ordering information |
| Cat. No: |
Description |
| 79-TIDAS-BASIC |
Tidas I Basic Spectrometer Module
with Spectralys Software |
| 79-TIDASI-FL |
Tidas I, FO-6000, LWCC2100, FO-400-SMA1M (2),
79-501609 |
| 79-TIDASI-SPT |
System Tidas I, D2LITE, SPT-2, UCK |
| 79-TIDASI-MV |
System Tidas I, Mvette, FO-200AS/SMA (two), LV140,
79-58200, D2LITE |
| 79-TIDASI-LWCC |
System Tidas I, LWCC 2100, FO-6000,
FO-400-SM1A(2), Sample injector79-58006, & Peri-Star Pump(79-500291) |
| 79-TIDASI-TIP |
Tidas I, DIP-UV, FO-6000, UCK |

6. Ultrapath™
VIS Absorbance System- A unique high-performance
Spectrophotometer |
A unique multiple pathlength sample cell for absorbance spectroscopy with
extended dynamic
range
 | Selectable pathlengths: 2, 10, 50 and 200 cm |
 | Broad dynamic range: 5 mAU/cm to 0.1 AU/cm
0.002m-1 to 200m- |
 | Excellent measurement repeatability: 5 mAU/cm |
 | Wavelength range: 380 nm to 800 nm |
 | Developed for the spectroscopic determination of colored dissolved
organic matter
(CDOM) in seawater and fresh water environments. |
|
|
UltraPath Specifications |
|
Dynamic range: |
5 mAU/cm to 1 AU/cm |
|
Wavelength range: |
380 – 730nm |
|
Wavelength resolution: |
5nm (FWHM) |
|
Number of diodes: |
256 |
|
Resolution: |
2.2nm/pixel |
|
Noise (peak to peak) |
< 0.2 mAU |
|
Drift: |
<0.5 mAU/h |
|
Dimensions: |
6.3 x 10.6 x 128” |
|
Inner diameter: |
2mm |
|
Cell volume (filling): |
10mL(at 200cm pathlength) |
|
Sample inlet/outlet: |
1/8” tubing |
|
Fiber input:
Fiber output: |
600 mm core diameter, SMA
400 mm core diameter, SMA |
|
Solvent resistance: |
Most organic and inorganic solvents |
|
System shipping weight: |
15 kg |
| |
Ordering information |
| Cat. No: |
Description |
| 79-UPVIS |
UltraPath- includes multiple pathlength cell, Tidas I
Spectrometer module with Spectralys
Software, FO-6000 light source, 400 mm and 600 mm optical fibers,
6-roller peristaltic
pump, silicone tubing, sample injector and waveguide cleaning kit
Specify line voltage |
| 79-501609 |
Waveguide Cleaning |
| 7. Miniature
Fiber Optic Spectrometers |
The SpectraUSB plugs into the USB port of any desktop or notebook pc,
eliminating the need for
separate analog-to-digital converters and interfacing cables.
|
|
SPECTRAUSB Specifications |
|
Connections: |
Universal serial Bus (USB)
RS-232 available on side (PC98 standard)
Master spectrometer channel only |
|
Operating software: |
SpectraWare
· Automatic scaling of X and Y axes during data collection.
· Autosave multiple scans to autoindexed files
· Math functions: Area, Ratio, Plus, Divide, Smooth, Plus K,
Derivative, Integrate, Log, Ln. Signal Averaging |
|
Data transfer rate: |
Full scans into memory every 13 ms.
Acquisition approximately every 25 ms |
|
Dimensions: |
89 x 64 x 34mm |
|
Weight: |
200gm |
| |
Ordering information |
| Cat. No: |
Description |
| 79-SPECTRAUSB |
Pre-set 200-850 nm, 25 μ slit, 1.5nm resolution |
| 79-USBVIS |
1cm cuvette + visible light source 390-950 nm |
| 79-SPECTRAUSB-MV |
Microtiter Sampling System
1(Protein analysis)
Includes SpectaUSB, MicroVette sample cell, LV140, 58200, D2LITE, FO-
200AS-SMA(2) |
| 79-SPECTRAUSB-SPT |
Microtiter Sampling System 2
Includes SpectaUSB, SPT, UCK, D2LITE |

| |
S2000 Specifications |
Detector:
CCD elements:
Well depth(@600nm): |
2048-element blue enhanced linear
silicon CCD array
2048 elements @12.5 x 200mm
350,000 photons |
| Dynamic range(system): |
2 x 108 |
| Dynamic
range(detector): |
~2000:1 |
| Sensitivity(estimated):
Effective range:
Integration speed:
|
86 photons/count
2.9 x 10-17 joule/count
2.9 x 10-17 watts/count(for 1-sec integration)
200 – 1100nm
Å 7.2 - 8 milliseconds to 4 seconds (with 500 kHz A/D card) |
Optics:
Gratings:
Slits:
Order-sorting filters:
Resolution:
Stray light:
Fiber optic connector:
|
14 grating choices, optimized for
UV, VIS, or NIR
10, 25, 50, 100, or 200 μm x 1000 μm
Permanently installed Schott glass longpass filters
Å 0.3 - 10.0 nm FWHM (depends on groove density of grating and diameter
of fiber or width of slit)
< 0.01% at 600 nm
< 0.10% at 435 nm
SMA905 connector to single strand optical fiber (0.22 NA)
|
| Dark noise: |
2.5-4.0(RMS counts) |
| Integration time: |
42 milliseconds to 60 seconds |


| |
Ordering information |
| Cat. No: |
Description |
| 79-S2000SGL |
Single beam, SpectraWare, A/D card(PCI),
cables |
| 79-S2000DBL |
Dual beam, SpectraWare, A/D
card(PCI), cables |
| 79-S2000-FL |
Fluorescence Detection System
Includes S2000, SpectraWare software package, cables, A/D Card (PCI),
350-1000nm, 200 μm slit, L2-low light upgrade, FO-6000 light source, FO-
600-SMA1M (two), CUV-UV-FL, CUV-MSP (two), CUV2051-1 |
| 79-S2000-LWCC |
Visible Detection System
(Colorimetric Analysis)
Includes S2000, software pkg, cables, A/D card(PCI), 350-850 nm, 50μm
slit, L2 low light upgrade, FO-6000, LWCC with 100cm pathlength,
FO-400-SMA1M (two), 501609. |
| 79-S2000-CUV |
Full range UV/VIS Detection System
Includes S2000, software pkg, cables, A/D card, UV2/L2 upgrades, 25μm
slit, OFLV, 200-850nm, D2LITE, FO-400-SMA1M (two), CUV-UV,
CUV2012-1 |
| |
Detector Upgrades |
| 79-L2 |
Low Light Upgrade: Detector Collection Lens
for S2000, installed per channel |
| 79-UV2 |
UV Detector Upgrade for S2000
Series, required for measuring at
wavelengths less than 350 nm, installed per channel |
| 79-OFLV-200-850 |
Multi-bandpass order-sorting detector coating,
installed per channel |
| 79-OFLV-350-850 |
Multi-bandpass order-sorting
detector coating,
installed per channel |
| 79-SLIT-XXX |
(other than 50 micron) 10, 25, 100, 200 /per channel |
Liquid Waveguide Capillary Cell(LWCC)

 | Liquid Waveguide Capillary Cells(LWCC) are optical cells that combine an
increased optical
pathlength (5-200 cm) with small sample volumes (12.5 – 500 mL). |
 | Ultra-sensitive absorbance measurements can be performed in the
ultraviolet(UV), visible(VIS) and
near-infrared(NIR) to detect low sample concentrations in a laboratory or
process control environment. |
 | Used in a variety of applications, such as liquid chromatography
detection and stopped-flow detection,
drinking water analysis, as well as environmental and oceanographic
monitoring systems. |
| Specifications |
79-LWCC-1 |
79-LWCC-2 |
| Wavelength Material: |
Low refractive index polymer |
Fused silica tubing coated with
a low refractive index polymer |
| Optical pathlength: |
5 – 100cm |
5 – 100cm |
| Inner diameter: |
500μm |
550μm |
| Internal volume: |
10 - 200μL |
13 - 240μL |
Sample Inlet/Outlet
Compression Fitting: |
1/16”, 1/32” |
1/16”, 1/32” |
| Fiber input (ID): |
400μm |
400μm |
| Maximum temperature: |
160º C |
160º C |
| Maximum pressure: |
1000 psi |
2000 psi |
| Minimum pressure: |
1.5 – 3 psi |
1.5 - 3 psi |
| Solvent resistance |
Most organic & inorganic solvents |
Most organic & inorganic solvents |
| Shipping weight: |
1.4 kg |
1.4 kg |
| |
Ordering
information |
| Cat. No: |
Description |
| 79-LWCC-1 |
Low refractive index polymer tubing,
pathlength=50 cm |
| 79-LWCC-1005 |
Low refractive index
polymer tubing, pathlength=5 cm |
| 79-LWCC-1010 |
Low refractive index polymer tubing,
pathlength=10 cm |
| 79-LWCC-1100 |
Low refractive index
polymer tubing, pathlength=100 cm |
| 79-LWCC-2 |
Fused silica tubing coated with a low
refractive index polymer pathlength=50 cm |
| 79-LWCC-2005 |
Fused silica tubing
coated with a low refractive index polymer pathlength=5 cm |
| 79-LWCC-2010 |
Fused silica tubing coated with a low
refractive index polymer pathlength=10 cm |
| 79-LWCC-2100 |
Fused silica tubing
coated with a low refractive index polymer pathlength=100 cm |
| 79-LWCC-2200 |
Fused silica tubing coated with a low
refractive index polymer pathlength=200 cm |
| 79-LWCC-2500 |
Fused silica tubing
coated with a low refractive index polymer pathlength=500 cm |
| 79-58006 |
Sample injector assembly |
| 79-500291 |
Peri-Star®
peristaltic pump , 6 roller for smooth injection |
| 79-FO-400-SMAIM |
Fiber optic cable, 1m, SMA, 400mm core,
UV-enhanced |
| 79-501609 |
Waveguide cleaning kit |
| 79-KITLWCC |
LWCC start-up kit. Includes
79-FO-400-SMAIM(2), 79-58006, -500291, -501609 |
SpectroPipettor
 | Ideally suited for protein and DNA analysis |
 | Sample volumes as small as 2 microliters |
 | Allows easy, quick and accurate spectroscopic measurements of small
sample volumes. |
| Specifications |
79-SPT |
79-SPT-2 |
Wavelength range
(with SpectroMate) |
230 – 850 nm |
230 – 850 nm |
| Sample volume: |
2 microliter |
2 microliter |
| Light path length of cell: |
1.0cm |
1.0cm |
| Temperature range: |
4 to 99º C |
4 to 99º C |
| Optical fiber length: |
1.3m |
1.3m |
Core diameter of launch
fiber(s): |
400μm |
200μm bundle (3) |
Core diameter of return
fiber: |
100μm |
200μm |
| |
Ordering information |
| Cat. No: |
Description |
| 79-SPT |
SpectroPipetter |
| 79-SPT-2 |
SpectroPipetter-II – Optical UV
efficiency |
| 79-SPT-UCK |
SpectroPipetter & Ultrasonic Cleaning Kit |
| 79-SPT-2-UCK |
SpectroPipetter-II & Ultrasonic
Cleaning Kit |
| 79-15807 |
Cleaning solution concentrate (125mL) |
| 79-UCK |